Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of the Korean Ophthalmological Society ; : 1552-1557, 2015.
Artigo em Coreano | WPRIM | ID: wpr-65427

RESUMO

PURPOSE: To evaluate the correlation between nuclear density measured using the Pentacam(R) (Oculus Optikgerate GmbH, Wetzlar, Germany) Scheimpflug imaging system and phacoemulsification parameters. METHODS: The nuclear density was measured using maximal nuclear density with ImageJ, Pentacam(R) nucleus staging (PNS), average value and maximal value in lens densitometry. Intraoperatively, effective phaco time (EPT) and balanced salt solution (BSS) used were noted and compared with the nuclear density calculation methods. As an index of corneal endothelial cells, the changes in cell density (CD) were compared with the nuclear density. RESULTS: Regarding EPT, maximal nuclear density with ImageJ (r = 0.379, p < 0.01) and PNS (r = 0.367, p < 0.01) were correlated positively, but the other methods were not correlated. Concerning BSS used, maximal nuclear density with ImageJ (r = 0.279, p = 0.03) and PNS (r = 0.286, p = 0.04) were positively correlated, but the other methods were not correlated. The specular microscopy showed that as the nuclear density increased, the postoperative CD tended to decrease, but without statistical significance. CONCLUSIONS: Preoperative nuclear density measurements using maximal nuclear density with ImageJ or PNS were correlated with phacoemulsification parameters.


Assuntos
Contagem de Células , Densitometria , Células Endoteliais , Microscopia , Facoemulsificação
2.
Journal of the Korean Ophthalmological Society ; : 1-5, 2015.
Artigo em Coreano | WPRIM | ID: wpr-190055

RESUMO

PURPOSE: We used computed tomography (CT) scans to describe normal Korean lacrimal gland volume and lacrimal gland size and then examined their correlations with patient age. METHODS: CT scans were obtained in 213 orbits of 111 patients who underwent CT from January to August of 2013. Aquarius iNtuition (TeraRecon, Foster City, CA, USA) software was used to outline the lacrimal gland in consecutive axial slices and to calculate the volume. RESULTS: The mean volume of the lacrimal gland was 0.589 cm3 in right orbits (SD = 0.090), 0.583 cm3 in left orbits (SD = 0.289), 0.596 cm3 in males (SD = 0.083), and 0.575 cm3 in females (SD = 0.094). There was no significant difference in mean lacrimal gland volume according to laterality (p = 0.614) or sex (p = 0.102) (2-sample t-tests). We investigated mean lacrimal gland volume in 3 age groups. Mean lacrimal gland volume was 0.630 cm3 (SD = 0.080) for the 20 to 40 year old group, 0.553 cm3 (SD = 0.734) for the 41 to 60 year old group, and 0.544 cm3 (SD = 0.885) for the older than 60 years old group. There was an inverse relationship between gland volume and age (Pearson r = -0.384, p = 0.00). CONCLUSIONS: The mean volume of the lacrimal gland decreased with age and there was no significant difference between right and left orbits or between male and female patients.


Assuntos
Feminino , Humanos , Masculino , Envelhecimento , Intuição , Aparelho Lacrimal , Órbita , Tomografia Computadorizada por Raios X
3.
Journal of the Korean Ophthalmological Society ; : 1693-1697, 2014.
Artigo em Coreano | WPRIM | ID: wpr-41557

RESUMO

PURPOSE: We present the results of visual evoked potential (VEP), electroretinography (ERG), and electrooculography (EOG) in normal subjects using the Mon-pack 3 system (Metrovision). METHODS: VEP, ERG, and EOG were obtained in 92 normal eyes. The measurements followed the International Society for Clinical Electrophysiology of Vision (ISCEV) standardization protocol. In VEP, the standard electrode was placed on the forehead and the active electrode was attached on the occiput. In ERG, a 20-minute dark adaptation was performed after mydriasis, and an ERG-jet electrode was used. EOG was measured by attaching an electrode to each medial canthal skin. Each latent period and electric potential was measured with average, standard deviation, median, and 95% confidencenterval (95% CI). RESULTS: The mean P100 latency in pattern VEP was 104.36 ms, and P100 latency in flash VEP was 116.71 ms. For the maximal ERG response, the implicit times of a and b waves were 22.65 ms and 44.58 ms, respectively and the amplitude of a and b waves were 274.09 microv and 489.52 microv, respectively. For the ERG cone response, the implicit time of a and b waves were 18.21 ms and 33.40 ms, respectively, and the amplitude of a and b waves were 35.87 microv and 104.42 microv, respectively. The mean ERG oscillitatory potential was 285.53 microv. The average EOG Arden ratio was 2.54. CONCLUSIONS: VEP, ERG, and EOG results from normal subjects using the Mon-pack 3 system can be applied to the diagnosis of retina and optic nerve disease and basic research.


Assuntos
Adaptação à Escuridão , Diagnóstico , Eletrodos , Eletroculografia , Eletrofisiologia , Eletrorretinografia , Potenciais Evocados Visuais , Testa , Midríase , Doenças do Nervo Óptico , Retina , Pele
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA